Cause all that matters here is passing the Network-Appliance NS0-520 exam. Cause all that you need is a high score of NS0-520 NetApp Certified Implementation Engineer - SAN. ONTAP exam. The only one thing you need to do is downloading Testking NS0-520 exam study guides now. We will not let you down with our money-back guarantee.

Check NS0-520 free dumps before getting the full version:

NEW QUESTION 1

A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 that is running ISCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.

  • A. Volume move
  • B. Volume rehost
  • C. Volume reallocation
  • D. Aggregate reallocation

Answer: B

Explanation:
Moving a Volume will only work if you are doing it within the same SVM
Volume Reallocation is used when you add new disks to an aggregate and you need to redistribute the data Aggregate Reallocation can be used only when you are moving data from an AFF filer to another AFF filer Rehosting a volume from one SVM to another SVM
Volume rehost enables you to reassign NAS or SAN volumes from one storage virtual machine (SVM, formerly known as Vserver) to another SVM without requiring a SnapMirror copy. The volume rehost procedures depend upon the protocol type and the volume type. Volume rehost is a disruptive operation for data access and volume management.
You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-vsmg%2FGUID-84308166-6872

NEW QUESTION 2

You must relocate a LUN from one AFF A700 HA pair to another AFF A300 HA pair while preserving all storage efficiencies. What are two ways to accomplish this task? (Choose two.)

  • A. Copy the volume.
  • B. Copy the LUN.
  • C. Move the volume.
  • D. Move the LUN.

Answer: AB

NEW QUESTION 3

A customer recently added two nodes with FC ports to a 4-node cluster.
Which SVM configuration is needed before the customer creates LUNs on the new nodes?

  • A. The FC service needs to be enabled on the data SVM.
  • B. The existing LIFs need to be migrated to the new nodes.
  • C. New FC LIFs need to be created on the cluster SVM.
  • D. New FC LIFs need to be created on the new nodes.

Answer: D

Explanation:
Reference: https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.exp-expand%2FGUID- E3BB89AF-6251-4210-A979-130E845BC9A1.html

NEW QUESTION 4

When does Fractional Reservation reserve space from the volume?

  • A. Volume Creation
  • B. LUN Creation
  • C. LUN SnapMirror
  • D. Volume Snapshot

Answer: D

NEW QUESTION 5

A database administrator needs to ensure that snapshot copies of database files across multiple LUNs are taken at the same point in time. Which action achieves this outcome?

  • A. Create each LUN within the same FlexVol volume
  • B. Create each LUN on the same Fabric Pool aggregate
  • C. Add each LUN volume to the same snapshot schedule
  • D. Create each LUN within the same FlexGroup Volume

Answer: A

Explanation:
We can discard Flexgroup because it only works on NAS Protocols.
We can discard LUNs and Aggregates because snapshots are not taken at that level
Snapshots are taken at volume level
You can find more information on this link:
https://community.netapp.com/t5/ONTAP-Discussions/can-we-creat-multiple-luns-from-same-volume-on-AFF3

NEW QUESTION 6

You want configure namespaces to support NVMe over Fibre Channel (NVMe/FC) using ONTAP 9.8. Which action will accomplish this task?

  • A. Add FC to the list of SVM protocols
  • B. Remove any protocols from the SVM before adding the NVMe protocol
  • C. Enable ALUA on the namespaces that should use the NVMe protocol
  • D. Configure a LIF for the NVMe protocol

Answer: D

Explanation:
Although ONTAP uses a NVMe/FC LIF that is separate from the FCP LIFs, both LIFs can be hosted on the same physical HBA port at both the host initiator and storage target. NVMe/FC and FCP can
share the same physical infrastructure concurrently, so the same physical port, cable, switch port, and target port can simultaneously host and transmit both FCP and NVMe/FC frames
NVMe can use the same FC infraestructure, but it needs to create a separate NVMe LIF to work. You can find more information on this link:
https://www.netapp.com/de/media/10681-tr4684.pdf (14)

NEW QUESTION 7

Which two features does Assymmetric Namespase Access (ANA) support? (Choose two.)

  • A. multipathing
  • B. LUN masking
  • C. LUN hosting
  • D. path management

Answer: AD

NEW QUESTION 8

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, what is the total amount of space that is guaranteed for the LUNs in the
/vo1/vo1_sanlunsiprod_03 volume?

  • A. 0 GB
  • B. 300 GB
  • C. 600 GB
  • D. 2600 GB

Answer: A

NEW QUESTION 9

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit, which FC LIF would cause a path failure on a host connecting to a LUN?

  • A. fcp_sanluns01prod02p0e
  • B. fcp_sanluns01prod02p0g
  • C. fcp_sanluns01prod02p0g
  • D. fcp_sanluns0lptodOlp0e

Answer: A

NEW QUESTION 10

When setting up a VLAN for administrative security purposes, which four ports are the only important ports to include in the VLAN? (Choose four.)

  • A. Storage Controllers Management Ethernet ports
  • B. FC Switches Ethernet port
  • C. Hosts iSCSI HBA Ethernet port
  • D. Ethernet Switches Management port
  • E. Storage Controller iSCSI Ethernet Target ports
  • F. Hosts NIC Ethernet port

Answer: ABDF

NEW QUESTION 11

After performing failover testing on a newly deployed MetroCluster configuration, some aggregates remain in a degraded state. Referring to the exhibit, which statement is true?
NS0-520 dumps exhibit

  • A. The MetroCluster Tiebreaker software is misconfigured
  • B. The ONTAP Mediator service is misconfigured
  • C. A cluster switch is powered off
  • D. A disk shelf is powered off

Answer: D

Explanation:
The aggregate with drives on the powered-off shelf should have a degraded RAID status, and drives on the affected plex should have a failed status
You can find more information on this link:
https://docs.netapp.com/us-en/ontap-metrocluster/install-ip/task_test_the_mcc_configuration.html#verifying-ope

NEW QUESTION 12

Exhibit.
NS0-520 dumps exhibit
You are asked to change the iSCSl Target Node Name of an SVM named SVM1 that is serving data. Referring to the exhibit, which two statements are correct? (Choose two.)

  • A. Reconnect all the lUNs alter renaming the target node.
  • B. Disable Selective LUN Mapping (SIM) and create port sets.
  • C. Unmap and re-map the LUNs.
  • D. Stop and start the iSCSI service.

Answer: CD

NEW QUESTION 13

You have implemented FabricPool on your AFF ASA ONTAP 9.8 Cluster. An archived database has become very active, and it requires FabricPool adjustments.
Which two steps are required to address this issue? (Choose two)

  • A. Use the promote cloud-retrieval-policy
  • B. Remove all snapshot copies.
  • C. Set the tiering-policy to none
  • D. Set the space-guarantee on the volume

Answer: AC

Explanation:
Promoting all data from a FabricPool volume to the performance tier.
You can proactively retrieve all data on a FabricPool volume in the Cloud and promote it to the performance tier.
Use the volume modify command to set tiering-policy to none and cloud-retrieval-policy to promote. You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-mgng-stor-tier-fp%2FGUID-45FEF77

NEW QUESTION 14

NS0-520 dumps exhibit
Referring to the exhibit, which two LIFs would be optimized paths to LUN /vol/OraDev_Vol/OraDev? (Choose two.)

  • A. aff_node-01_0g_A
  • B. aff_node-02_0e_A
  • C. aff_node-02_0g_A
  • D. aff_node-01_0e_A

Answer: A

NEW QUESTION 15

Which two are supported in ONTAP 9.5? (Choose two.)

  • A. an NVMe LIF and an FC LIF in the same SVM
  • B. an NVMe LIF associated with an FC Direct Connect port
  • C. a NVMe LIF and an FC LIF associated with the same port
  • D. multiple NVMe LIFs in the same SVM

Answer: CD

NEW QUESTION 16

Click the Exhibit button.
NS0-520 dumps exhibit
During pre-deployment testing, you want to ensure that all FC paths are available to your host. You use the network interface modify -vserver SVM1 -lif LIF_top-0f -admin-state up command to correct the configuration shown in the exhibit.
What happens when using this command?

  • A. It creates a new LIF on SVM2 named up.
  • B. It creates a new LIF on SVM1 named LIF_top-0f.
  • C. It changes the administrative state from “down” to “up”.
  • D. It changes the operational state from “down” to “up”.

Answer: C

NEW QUESTION 17

An administrator is configuring their Ethernet switches to support an AFF A300 cluster that will be providing iSCSI LUNs to servers. The switches are also used for other traffic from various hosts.
In this scenario, which statement about the switch configuration is correct?

  • A. Use a larger MTU size at the SAN connection rather than the host connections to allow for greater SAN bandwidth.
  • B. Use network ports as access ports only.
  • C. Use multiple VLANs to segregate iSCSI traffic from other traffic types
  • D. Use a single VLAN to consolidate all data traffic on the switches.

Answer: A

NEW QUESTION 18

You are configuring a 4-node AFF A400 ONTAP 9.8 cluster. The data center switches have limited ports, and you are given one 10-Gigabit Ethernet port per node for external access.
In this scenario, which three protocols share the same physical port? (Choose three)

  • A. NVMe/FC
  • B. ISCSI
  • C. FCoE
  • D. Snapmirror
  • E. FC

Answer: BCD

Explanation:
If we have only ethernet switches available, we can only enable protocols over ethernet such as FCoE, ISCSI and Snapmirror.
NVMe/FC and FC need a SAN Fabric switch to work.

NEW QUESTION 19

NS0-520 dumps exhibit
Referring to the exhibit, which two elements are required for NVMe host access with ONTAP 9.5 and using supported AFF nodes? (Choose two.)

  • A. You need 16 Gb FC HBAs installed in the AFF nodes.
  • B. You must have the license installed for NVMe support in the cluster.
  • C. You must have the license installed for FC support in the cluster.
  • D. You need 32 Gb FC HBAs installed in the AFF nodes.

Answer: CD

NEW QUESTION 20
......

100% Valid and Newest Version NS0-520 Questions & Answers shared by Downloadfreepdf.net, Get Full Dumps HERE: https://www.downloadfreepdf.net/NS0-520-pdf-download.html (New 234 Q&As)