Q22. For a KVM session to be successful, which two of these need to be done? (Choose two.) 

A. The Cisco IMC IP address needs to be assigned on the Admin tab. 

B. The Cisco IMC IP address needs to be in the same subnet as the management IP. 

C. The Cisco IMC needs to be upgraded to the same version as the UCS Manager. 

D. The server needs to be fully discovered. 

Answer: AD 


Q23. A customer is troubleshooting QoS in a Cisco UCS domain due to high packet drops in the network. The customer has configured the vNIC and associated QoS policy, and changed the MTU from 1000 to 1200. Packet drops still exist. What is the cause of this issue? 

A. The MTU specified here must be greater than the MTU specified in the associated QoS system class. If this MTU value is less than the MTU value in the QoS system class, packets may be dropped during data transmission. 

B. The MTU specified here must be equal to or less than the MTU specified in the associated QoS system class. If this MTU value exceeds the MTU value in the QoS system class, packets may be dropped during data transmission. 

C. The MTU specified here must be less than the MTU specified in the associated QoS system policy. If this MTU value exceeds the MTU value in the QoS system policy, packets may be not be dropped during data transmission. 

D. The MTU must be optimized and should be changed to fc with the CLI command set mtu fc. 

Answer:


Q24. While updating firmware in a Cisco UCS environment, what will the Cisco UCS Manager do? 

A. show you all versions available on Cisco.com 

B. show you all versions downloaded to the Cisco UCS Manager 

C. show you only versions that are supported in your environment 

D. show you only versions that you selected to show 

E. show you old and new versions from your download 

Answer:


Q25. If a server is not associated with a service profile, the activated firmware remains pending. Which two steps should you take? (Choose two.) 

A. Manually reboot the server. 

B. Reset the server to a new profile. 

C. Reset the unassociated server to activate the firmware. 

D. Reinitialize the firmware process with Cisco UCS Manager. 

E. Download the firmware and start over. 

F. Shut down gracefully and start over. 

Answer: AC 


Q26. On a Cisco UCS B-Series data center environment; how many default roles are there when utilizing RBAC for security restriction? 

A. 1 

B. 5 

C. 10 

D. 15 

E. 20 

Answer:


Q27. You are installing Microsoft Windows Server 2008 R2 on a Cisco UCS C210 M2 server, and the installer does not see local storage on the LSI MegaRAID SAS 9260-4i controller that is installed. Which statement explains the issue? 

A. The driver is not included in the installer DVD. Press F6 to load the LSI RAID driver from CD or virtual media. 

B. The virtual disk is not created and online. 

C. The LSI 9260-4i is only supported by Red Hat Enterprise Linux and VMware vSphere 

4.0 and later. 

D. The installer DVD for Microsoft Windows Server 2008 R2 did not include the LSI driver until SP2. 

Answer:


Q28. A customer calls in a trouble ticket complaining of unacceptable read I/O latency on a Cisco UCS C210 M2 server with an LSI MegaRAID 9260-8i with an 8-disk RAID-10 virtual disk. As you validate the RAID controller configuration, which of these configured items impacts read performance at the controller level? 

A. all disks are 146GB 6 Gb SAS 15K RPM SFF 

B. read ahead cache is enabled 

C. BGI rate = 0 

D. strip size = 256k 

E. no hot spare 

Answer:


Q29. During the installation of Windows 2008 64-bit operating system on a Cisco UCS server, the RAID controller is not found. What is the cause of the problem? 

A. The Cisco IMC firmware needs to be updated. 

B. The LSI option ROM needs to be configured by pressing Ctrl-H during post. 

C. The LSI drivers are not bundled and need to be loaded by clicking the Load Driver option to point to the correct drivers. 

D. Windows 2008 64-bit operating system is not supported on Cisco UCS servers. 

Answer:


Q30. Which statement is true about system event logs? 

A. By default, they require manual clearing. 

B. They report operating system crashes and errors. 

C. They are also referred to as system error logs. 

D. They can only be accessed from Cisco UCS Manager. 

Answer:


Q31. How will the Cisco UCS Manager react when all of the FSM tasks fail? 

A. retries for 60 seconds 

B. raises faults and alarms 

C. restarts from the previous known good task 

D. sends an NOC SNMP trap email 

Answer:


Q32. Which two types of ports does end host mode switching have? (Choose two.) 

A. VSS 

B. border 

C. router 

D. server 

E. STP 

F. client 

Answer: BD 


Q33. A customer is trying to boot an operating system that is installed on the eUSB on a Cisco UCS B-Series blade server; however, the boot fails. What is the cause of this failure? 

A. The local disk must be the first device in the boot order. 

B. eUSB is not a supported boot device. 

C. eUSB support is available only on the Cisco UCS C-Series rack server. 

D. eUSB is not the first device in the boot order for the server. 

Answer:


Q34. What is the maximum number of boot targets for an FCoE vHBA on a Cisco UCS C-Series server? 

A. 1 

B. 2 

C. 3 

D. 4 

Answer:


Q35. When using the Cisco UCS Manager GUI to troubleshoot a suspected bad memory, which 

logs contain data that are related to the faulty DIMM? 

A. the System Event log and Faults log that are located under the Admin tab 

B. the Events log and Faults log that are located under the Admin tab 

C. the System Event log that is located under the Server tab in the Navigation panel and the Faults log that is located under the Admin tab 

D. the System Event log that is located under the Equipment tab and the Faults log that is located under the Admin tab 

Answer:


Q36. A local storage installation of ESX on a Cisco UCS C-Series server has failed due to local storage issues. What is the cause of the problem? 

A. LSI drivers are not bundled with ESX. 

B. The hard drive has a 1-TB partition size. 

C. The server only has an onboard controller, while ESX requires an LSI RAID controller card. 

D. ESX is not supported on Cisco UCS C-series servers. 

Answer:


Q37. Which protocols can be used to send to Cisco TAC (Technical Assistance Center) the show tech-support command output information about the Cisco UCS domain? (Choose two.) 

A. TFTP 

B. FTP 

C. SCP 

D. Telnet 

E. SecureTelnet 

Answer: BC 


Q38. A customer is configuring SAN pin groups in a Cisco UCS domain. The customer notices that pinning is not working and traffic from the vHBA is not passing over the Fibre Channel uplink port. Which of these must be done for pinning to work correctly? 

A. Include the SAN pin group in a vHBA policy and then include the vHBA policy in the service profile that is assigned to that server. 

B. Include the SAN policy in the Cisco UCS Manager to match with pin groups on the fabric interconnect. 

C. The customer must have Cisco UCS Manager version 2.0 or above. 

D. Fibre Channel switch mode needs to be configured first. 

Answer:


Q39. Which three are valid tech support bundles to collect in the local management shell? (Choose three.) 

A. UCSM 

B. UCSM-MGMT 

C. Port-Channel 

D. Adapter 

E. SAN 

F. FEX 

Answer: ABF 


Q40. A customer is configuring a network control policy in a Cisco UCS domain. The network control policy configures the network control settings for the Cisco UCS domain, including which three of these? (Choose three.) 

A. how the VIF behaves if no uplink port is available in end-host mode 

B. the action that the Cisco UCS Manager takes on the remote Ethernet interface, vEthernet interface, or vFibreChannel interface when the associated border port fails 

C. Layer 2 switching on the fabric interconnect 

D. whether MAC registration occurs on a per-vNIC basis or for all VLANs 

E. the end-host mode setting on the I/O module 

Answer: ABD 


Q41. Which log file in Cisco UCS Manager contains information about which user took a specific action? 

A. user access log 

B. system change log 

C. audit log 

D. access control log 

Answer:


Q42. Which of these does not have an FSM associated with it? 

A. vCenter connection 

B. service profile 

C. server hardware 

D. service profile templates 

Answer: