We provide real NS0-157 exam questions and answers braindumps in two formats. Download PDF & Practice Tests. Pass Network Appliance NS0-157 Exam quickly & easily. The NS0-157 PDF type is available for reading and printing. You can print more and practice many times. With the help of our Network Appliance NS0-157 dumps pdf and vce product and material, you can easily pass the NS0-157 exam.
Q1. - (Topic 1)
To achieve high-availability within a FAS8080 EX HA pair, which two requirements are needed? (Choose two.)
A. Connect the NVRAM HA interconnects of the HA pairs.
B. Connect multiple paths from the controllers to the host.
C. Connect the local node to the partner node’s disk shelves.
D. Enable auto-giveback.
Answer: A,B
Q2. - (Topic 2)
Which statement is true about establishing a SnapMirror relationship?
A. It sets up the relationship on the source node only.
B. It sets up the relationship and starts the initial data transfer.
C. It sets up the relationship and creates the destination volume.
D. It sets up the relationship, but does not start the initial transfer.
Answer: D
Explanation:
Link: http://support.netapp.com/documentation/docweb/index.html?productID=61651
Q3. - (Topic 3)
Which of the following statements is true about a Flash Pool?
A. A 32 bit or 64 bit aggregate containing SSDs and HDDs
B. A 32 bit aggregate containing SSDs and HDDs
C. A 64 bit aggregate containing SSDs and HDDs
D. A 64 bit aggregate containing only SSDs
Answer: C
Q4. - (Topic 3)
Which two Vservers are created automatically by the cluster setup process? (Choose two)
A. Admin
B. Data
C. Management
D. Node
E. Protocol
Answer: A,D
Q5. - (Topic 1)
Which two default SVM roles are available when an SVM is created? (Choose two.)
A. vsadmin-readonly
B. root
C. vsadmin
D. admin
Answer: A,C
Reference: https://library.netapp.com/ecmdocs/ECMP1368701/html/GUID-FFE11F8C-490B-4D6D-A18E-3488275029C7.html(See the table 1st point and last point).
Q6. - (Topic 3)
New systems are shipped with the root volume in a 64-bit aggregate starting with which Data ONTAP release?
A. 8.0.0
B. 8.0.1
C. 8.0.2
D. 8.1
Answer: D
Explanation: Explanation/Reference: https://library.netapp.com/ecmdocs/ECMP1196798/html/GUID-A60F4F83-0034-4DB8-838B-06E9D4BEF9A4.html
Q7. - (Topic 3)
Identify two synchronous Fpolicy applications:
A. Data motion service
B. Encryption and decryption services
C. Logical interface migration management
D. File archiving and hierarchical storage management
Answer: B,D
Explanation:
https://library.netapp.com/ecmdocs/ECMP1196891/html/GUID-FFAEA690-552D-4261-A1B9-04DA99932DF0.html
Q8. - (Topic 1)
What is the maximum number of nodes allowed in an FAS8000 series with a SAN configuration?
A. 24
B. 8
C. 4
D. 2
Answer: B
Explanation: SAN: Up to 8 cluster nodes Reference: http://cloudcarib.com/pdf/NetApp-8000.pdf
Q9. - (Topic 1)
Which two must already exist before creating a subnet? (Choose two.)
A. storage virtual machine
B. failover group
C. broadcast domain
D. IPspace
Answer: C,D
Reference: http://www.bradreese.com/how-to-subnet-a-network.pdf
The IPspace feature enables a single storage system to be accessed by clients from more than one disconnected network, even if those clients are using the same IP address.
An IPspace defines a distinct IP address space in which vFiler units can participate. IP addresses defined for an IPspace are applicable only within that IPspace. A distinct routing table is maintained for each IPspace. No cross-IPspace traffic routing happens.
https://library.netapp.com/ecmdocs/ECMP1155585/html/GUID-4C8A392E-290E-4F9C-91E8-EBF3E2047B06.html
Q10. - (Topic 2)
What three statements are true about LIF failover? (Choose three.)
A. A node management Ethernet LIF will never automatically revert back to its home port.
B. A node management Ethernet LIF can fail over to its partner node when a port is down.
C. A data Ethernet LIF will not automatically revert back to its home port.
D. A cluster management Ethernet LIF will never automatically revert back to its home port
E. A cluster management Ethernet LIF can fail over when a port is down.
F. A data Ethernet LIF can fail over when the cluster is in quorum.
Answer: B,C,E
Explanation: https://library.netapp.com/ecmdocs/ECMP1401193/html/GUID-6DBD40F8-EA21-42AE-82CF-AEB556BEC783.html
"Scenarios that cause a LIF failover
LIF failover occurs in scenarios such as port failure, network interface failure, or cable failure. LIFs can be associated with failover rules that enable you to reroute the network traffic to other available ports in the cluster.
LIF failover occurs in the following scenarios:
When there is a power failure When automatic revert is enabled on a LIF and that LIF's home port reverts to the
administrative up status The LIF automatically migrates back to the home port. When the port hosting a LIF is in the administrative down status The LIFs move to another port. When a node reboots or falls out of quorum The LIFs on that node fail over to the ports on other nodes. If a node returns to quorum, the
LIFs automatically revert to the ports on the node, provided the ports are the home ports for
the LIF and automatic revert is enabled on the LIF.
For more information about quorum, see the Clustered Data ONTAP System
Administration Guide for Cluster Administrators.
When automatic revert is enabled on a LIF and that LIF's home port reverts to the administrative up status the LIF automatically migrates back to the home port."
Q11. - (Topic 1)
Which NetApp management tool configures AutoSupport for nodes in a cluster?
A. OnCommand System Manager
B. ConfigAdvisor
C. OnCommand Performance Manager
D. OnCommand Insight
Answer: A
Q12. - (Topic 3)
What are two capabilities of Vserver setup? (Choose two)
A. It licenses Vserver functionality
B. It joins an exisiting Vserver to the cluster.
C. it creates a new Vserver that can host FCP LUNs.
D. It creates a new cluster Vservers
E. It configures an existing Vserver
Answer: D,E
Explanation: https://library.netapp.com/ecmdocs/ECMP1196798/html/GUID-68CC383E-06E6-48AF-B7F5-8B510750EDDE.html
Q13. - (Topic 1)
When you use the volume snapshot autodelete command, what are three values for the commitment parameter? (Choose three.)
A. disrupt
B. volume
C. snap-reserve
D. try
E. destroy
Answer: A,D,E
Explanation:
https://library.netapp.com/ecmdocs/ECMP12452955/html/volume/snapshot/autodelete/mod ify.html
Q14. - (Topic 3)
Which are types of failover groups? (choose all that apply)
A. System-defined
B. User-defined
C. Next Available
D. Priority
E. Clusterwide
Answer: A,B,E
Explanation: Types of failover groups
Failover groups for LIFs can be system-defined or user-defined.
Additionally, a failover group called clusterwide exists and is maintained automatically.
Failover groups are of the following types:
System-defined failover groups: Failover groups that automatically manage LIF failover
targets on a per-LIF basis.
This is the default failover group for data LIFs in the cluster.
For example, when the value of the failover-group option is system-defined, the system will
automatically manage the LIF failover targets for that LIF, based on the home node or port
of the LIF.
Note: All the network ports should be assigned correct port roles, and all the network ports
of the same role should be in the same subnet.
User-defined failover groups: Customized failover groups that can be created when the
system-defined failover groups do not meet your requirements.
For a system with ports of the same role connected to multiple subnets, each LIF requires
a user-defined failover group with a failover group for each subnet.
You can create a failover group consisting of all 10-GbE ports that enables LIFs to fail over
only to the high-bandwidth ports.
Clusterwide failover group: Failover group that consists of all the data ports in the cluster.
This is the default failover group for the cluster-management LIFs only.
For example, when the value of the failover-group option is cluster-wide, every data port in
the cluster will be defined as the failover targets for that LIF."
https://library.netapp.com/ecmdocs/ECMP1401193/html/GUID-9600E800-B8E6-4A78-B97B-912459BEFD63.html
Q15. - (Topic 1)
Which statement describes a MetroCluster environment in clustered Data ONTAP?
A. A single cluster at each site interconnected using FC switches and Ethernet switches.
B. A single cluster at each site interconnected using FC switches only.
C. A single HA pair cabled across sites using FC switches.
D. A single HA pair stretched across sites using extended cables.
Answer: B
Explanation:
http://www.unitis.hu/downloads/MetroClusterContinuousAvailabilitySEPresentation_.pdf
Q16. - (Topic 3)
Which two actions protect an Infinite volume from the loss of a namespace constituent? (Choose two)
A. Minor the namespace constituent by using an intracluster data protection mirror
B. Mirror the namespace constituent by using an Intercluster data protection mirror
C. Mirror the namespace constituent by using a load-sharing mirror
D. Mirror the namespace constituent by using a FlexCache mirror
Answer: B,C
Explanation: http://www.globbtv.com/microsite/18/Adjuntos/_TR-4078_INFINITEVOLUME_BPG.PDF