The benefit from Pass4sures Network Appliance NS0-157 exam products is that they may enable the candidates to obtain certified in a shortest period and using little cash. So it really is a sensible decision to suit your needs to make. Each of the Network Appliance Network Appliance practice questions and answers include the fruits of our own dedicated professionals. They are sparing no initiatives to offer you the particular high-quality and valued Network Appliance NS0-157 training materials. Our own customers before you feel at ease while they make use of the Network Appliance Network Appliance examination engine. Nearly all of them get passed the specific exam with full confidence and get a high score. Pass4sure is preferred by our buyers because of the particular high appreciated good results ratio. However, in case you unluckily get failing in the Network Appliance Network Appliance exam, you are able to enjoy the particular full refund of purchasing service fees policy.

2021 Oct NS0-157 free exam questions

Q61. - (Topic 2) 

Clustered Data ONTAP 8.2 adds support for which following NAS protocol features? (choose 5) 

A. NAS auditing 

B. Local users and groups 

C. Offlline files 

D. File access 

E. Roaming profiles 

F. IPv6 

Answer: A,B,C,E,F 


Q62. - (Topic 1) 

What is true about a node root volume? 

A. There is a root volume on every node in a cluster. 

B. It is the root of a data SVM’s namespace. 

C. You can use vol move to move it to an aggregate on a different node. 

D. It is the most secure place to store critical user data. 

Answer:

Reference: https://library.netapp.com/ecmdocs/ECMP1196798/html/GUID-A60F4F83-0034-4DB8-838B-06E9D4BEF9A4.html 


Q63. - (Topic 2) 

When using Data ONTAP 8.1 Cluster-Mode and later, what is the default for new aggregates? 

A. 32-bit aggregates 

B. 64-bit aggregates 

C. 128-bit aggregates 

D. cluster aggregates 

E. traditional aggregates 

F. Vserver aggregates 

Answer:

Explanation: 

https://library.netapp.com/ecmdocs/ECMP1196986/html/GUID-D9F611BC-F7B4-4057-A76B-357BBAB7002F.html 


Q64. - (Topic 3) 

What are the four replicated database rings in a cluster? (choose four) 

A. administrator 

B. logical-interface manager (lifmgr) 

C. management application (mgmt) 

D. protocol management daemon (prtodb) 

E. SAN management deamon (bcomd) 

F. virtual-interface manager (vifmgr) 

G. volume location database (vldb) 

Answer: C,E,F,G 

Explanation: 

https://library.netapp.com/ecmdocs/ECMP1196798/html/GUID-C8F1D8ED-7420-48CC-8CC8-FF0A80399AA0.html 


Q65. - (Topic 2) 

In transitioning SnapVault relationships from 7-mode to clustered Data ONTAP, which statements are true? (Choose three) 

A. You are required to re-create all Snapvault relationships with new baseline 

B. You can plan on fan-in relationships of many source volume to one destination volume 

C. You can plan on fan-in relationships at the system level, many volumes to one Vserver 

D. You can plan on SnapMirror to SnapVault cascades 

Answer: A,C,D 


Up to the minute NS0-157 practice exam:

Q66. - (Topic 2) 

What three statements are true about LIF failover? (Choose three.) 

A. A node management Ethernet LIF will never automatically revert back to its home port. 

B. A node management Ethernet LIF can fail over to its partner node when a port is down. 

C. A data Ethernet LIF will not automatically revert back to its home port. 

D. A cluster management Ethernet LIF will never automatically revert back to its home port 

E. A cluster management Ethernet LIF can fail over when a port is down. 

F. A data Ethernet LIF can fail over when the cluster is in quorum. 

Answer: B,C,E 

Explanation: https://library.netapp.com/ecmdocs/ECMP1401193/html/GUID-6DBD40F8-EA21-42AE-82CF-AEB556BEC783.html 

"Scenarios that cause a LIF failover 

LIF failover occurs in scenarios such as port failure, network interface failure, or cable failure. LIFs can be associated with failover rules that enable you to reroute the network traffic to other available ports in the cluster. 

LIF failover occurs in the following scenarios: 

When there is a power failure When automatic revert is enabled on a LIF and that LIF's home port reverts to the 

administrative up status The LIF automatically migrates back to the home port. When the port hosting a LIF is in the administrative down status The LIFs move to another port. When a node reboots or falls out of quorum The LIFs on that node fail over to the ports on other nodes. If a node returns to quorum, the 

LIFs automatically revert to the ports on the node, provided the ports are the home ports for 

the LIF and automatic revert is enabled on the LIF. 

For more information about quorum, see the Clustered Data ONTAP System 

Administration Guide for Cluster Administrators. 

When automatic revert is enabled on a LIF and that LIF's home port reverts to the administrative up status the LIF automatically migrates back to the home port." 


Q67. - (Topic 2) 

When a pNFS 4.1 client is connected to a LIF on node 2 of an 8 node clustered Data ONTAP pNFS 4.1 Vserver, and the data volume being read is moved to node 1, which statement is true? 

A. The client redirects from a LIF on node 2 to a LIF on node 1 if available and continues data access uninterrupted. 

B. The client stays connected to a LIF on node 2 and accesses the data on node 1 through the cluster network. 

C. DNS records are updated and the client moves access to a LIF on node 1 from DNS referral. 

D. When a data volume is moved, only CIFS clients are affected. 

Answer:


Q68. - (Topic 2) 

What three statements are true about LIF failover? (Choose three.) 

A. A data Ethernet LIF fails over when the cluster is in quorum. 

B. A cluster management Ethernet LIF fails over when a port is down. 

C. A cluster management Ethernet LIF will never automatically revert back to its home port. 

D. A data Ethernet LIF will not revert back by default to its home port. 

E. A node management Ethernet LIF fails over when a port is down. 

F. A node management Ethernet LIF will never automatically revert back to its home port. 

Answer: A,D,F 


Q69. - (Topic 1) 

You have two LIFs homed on the same single-mode interface group. You want to leverage both 10 Gb interfaces as active/active. 

What must you do to use both 10 Gb interfaces? 

A. Move one of the LIFs to another node in the cluster. 

B. Delete the interface group, and home each LIF to one port each. 

C. Create another single-mode interface group and move one LIF to it. 

D. Change the ifgrp distribution function from the default IP setting to MAC. 

Answer:


Q70. - (Topic 2) 

Which of these correctly describes single-node clusters? 

A. They support storage failover 

B. They support nondistruptive upgrade 

C. They have no cluster LIFs 

D. They are identical to one-node clusters 

Answer: