Want to know features? Want to lear more about experience? Study . Gat a success with an absolute guarantee to pass Cisco 300-175 (DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)) test on your first attempt.
Cisco 300-175 Free Dumps Questions Online, Read and Test Now.
NEW QUESTION 1
This question concerns the power system of a Cisco Unified Computing System. Drag the options on the left to the right side in the correct order.
Answer:
Explanation: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Infrastructure-M
NEW QUESTION 2
You have a Cisco UCS B200 M2 server configured with 12 4-GBDDR3 1333-MHz dual-voltage memory DIMMs. You learned that the server memory speed is running at 1066 MHz instead. How can you configure the server to run at maximum memory speed?
- A. You cannot configure memory speed of 1333 MH
- B. The maximum memory speed of a Cisco UCS B200 M2 server with 12 4-GBDIMM is 1066 MHz.
- C. Memory speed of the ESX host is configurable on VMware vCenter.
- D. Create a BIOS polic
- E. In the RAS Memory BIOS settings, select Performance Mode for LV DDR Mode.
- F. On the CIMC of the Cisco UCS B200 M2, select 1333 MHz in the Memory Speed option.
Answer: C
NEW QUESTION 3
You need to upgrade the firmware on 15 Cisco UCS C-Series Rack Servers. Ten of the servers are integrated in a Cisco UCS cluster, and the other five servers are used in standalone mode. The Cisco UCS C-Series Rack-Mount Server Software Bundle is available.
Which set of statements about the upgrade process is true?
- A. You cannot upgrade the firmware on the servers in standalone mod
- B. You must cluster the servers first over LAN or via cluster interface
- C. After the firmware upgrade, you can revert the five servers to standalone mode.
- D. You cannot use the Cisco UCS C-Series Rack-Mount Server Software Bundle with Cisco UCS C-Series Servers in standalone mod
- E. You must download and use the Cisco UCS C-Series Rack-Mount Standalone Server Software package.
- F. First, you must integrate the standalone servers into the Cisco UCS syste
- G. Then, you can upgrade the firmware on all 15 servers from Cisco UCS Manage
- H. Finally, you can revert the five servers to standalone mode.
- I. You can upgrade the firmware on all of the Cisco UCS C-Series Rack Servers by using the Cisco UCS C-Series Rack-Mount Standalone Server Softwar
- J. You can upgrade the 10 servers that are integrated in a Cisco UCS cluster in Cisco UCS Manager, and you can upgrade the five standalone servers one by one.
Answer: D
Explanation: Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm3-1/b_C-SeriesIntegrati
NEW QUESTION 4
Refer to the exhibit.
Which result of configuring ServiceProfile 1 is true?
- A. It upgrades the firmware immediately.
- B. It restricts editing of ServiceProfile 1 to the members of the user 1 group.
- C. It associates the fw 1 firmware policy to ServiceProfile 1.
- D. It sets the firewall policy on the host to fw 1.
Answer: C
NEW QUESTION 5
View the Exhibit.
Refer to the exhibit. Which type of FCoE topology is displayed?
- A. direct-attach
- B. remote-attach
- C. vPC
- D. FCoE with Cisco 2232 Fabric Extenders
Answer: B
Explanation: Reference:
https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-series-switches/white_paper_c11-56040
NEW QUESTION 6
You need to identify which DCB standard provides these functionalities: negotiation capabilities for features, the distribution of parameters from one node to another, and logical link up and down signaling for both Ethernet and Fibre Channel interfaces.
Which DCB standard should you identify?
- A. ETS
- B. PFC
- C. DCBX
- D. QCN
Answer: C
NEW QUESTION 7
What is the Overlay Transport Virtualization site VLAN used for?
- A. to allow multiple site AEDs to communicate with each other
- B. to detect devices at the site that are not capable of OTV
- C. to facilitate communications between OTV edge devices within the site
- D. to allow the join interfaces at different sites to communicate
Answer: C
NEW QUESTION 8
Which of the following is true with respect to recovery from failure with automatic pinning that is configured on a cluster of Cisco Unified Computing System 62XX Fabric Interconnects?
- A. By default, server MAC addresses are pinned to uplink interfaces using PIN groups.
- B. When a northbound fabric interconnect link goes down, the affected servers will use NIC teaming to re-establish connectivity on the second fabric interconnect.
- C. When a northbound fabric interconnect link goes down, the fabric interconnect will send a gratuitous ARP to the northbound switch to announce the servers on the new port.
- D. In the event that all uplink ports on the fabric interconnect lose connectivity, the 22XX I/O module shuts down all of the host ports until at least one uplink is restored.
Answer: C
NEW QUESTION 9
Refer to the exhibit.
What statement is true regarding this setup created by this configuration?
- A. The NIC bypasses the kernel when sending and receiving networking packets
- B. The applications interact directly with the OS Kernel
- C. All of the other vNICs in the server are deleted and replaced by the usnic.
Answer: B
Explanation: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/usnic/c/deployment/2_0_X/b_Cisco_usNIC_Dep
NEW QUESTION 10
You configure FCoE in a Cisco UCS system at a customer site. The configuration seems correct, but the customer complains that the system fails to perform as expected. FCoE VLAN discovery, FCF discovery and FLOGI processes work properly. The issue appears to be with the Fibre Channel commands and responses.
What is a possible cause of the issue?
- A. The storage device is experiencing configuration or compatibility issues when the FIP process completes successfully.
- B. The routed Layer 3 network between the FCoE SAN and the storage device is experiencing issues when the FIP process fails to complete successfully.
- C. The FCoE configuration is experiencing errors because of issues with the Fibre Channel commends.
- D. The switched Layer 2 network between the FCoE SAN and the storage device is experiencing issues when the FIP process fails to complete successfully.
Answer: B
Explanation: Make sure that your native vlan is carried across all the trunk ports.
Reference:
https://supportforums.cisco.com/t5/storage-networking/fip-and-native-vlan/td-p/2451783
NEW QUESTION 11
You need to configure a Fibre Channel device alias named TEST for a device that is attached to port fc1./9 of a Cisco Nexus Series switch in a Cisco UCS system. Based on the output below, which command set should you use?
- A. SITE-A-MDS-Fabric-A# device-alias databaseSITE-A-MDS-Fabric-A (device-alias-db)# device-alias name TEST pwwn 50:00:14:40:47:b0:0c:f5SITE-A-MDS-Fabric-A (config-device-alias-db)# device-alias commit
- B. SITE-A-MDS-Fabric-A# configure terminalSITE-A-MDS-Fabric-A (config)# device-alias databaseSITE-A-MDS-Fabric-A (config-device-alias-db)# device-alias name TEST pwwn 50:00:14:42:d0:0c:f5:20SITE-A-MDS-Fabric-A (config-device-alias-db)# device-alias commit
- C. SITE-A-MDS-Fabric-A# configure terminalSITE-A-MDS-Fabric-A (config)# device-alias databaseSITE-A-MDS-Fabric-A(config-device-alias-db)# device-alias name TEST pwwn 50:00:14:40:47:b0:0c:f5SITE-A-MDS-Fabric-A (config-device-alias-db)# device-alias commit
- D. SITE-A-MDS-Fabric-A# configure terminalSITE-A-MDS-Fabric-A (config)# device-alias databaseSITE-A-MDS-Fabric-A (config-device-alias-db)# device-alias name TEST pwwn 50:00:14:42:d0:0c:f5:20SITE-A-MDS-Fabric-A (config-device-alias-db)# exit
Answer: A
NEW QUESTION 12
To provide stronger authentication for Cisco UCS manager, You are installing a third-party certificate from a trusted point. Which format must the certificate be in?
- A. DER
- B. PEM
- C. CRT
- D. CER (x.509)
Answer: D
Explanation: Trusted Points
To provide stronger authentication for Cisco UCS Manager, you can obtain and install a third-party certificate from a trusted source, or trusted point, that affirms the identity of your device. The third-party certificate is signed by the issuing trusted point, which can be a root certificate authority (CA) or an intermediate CA or
trust anchor that is part of a trust chain that leads to a root CA. To obtain a new certificate, you must generate a certificate request through Cisco UCS Manager and submit the request to a trusted point.
Important:
The certificate must be in Base64 encoded X.509 (CER) format.
NEW QUESTION 13
Which two elements are defined in a dynamic vNIC connection policy? (Choose two.)
- A. adapter policy
- B. QoS policy
- C. network control policy
- D. number of dynamic vNICs
- E. jumbo frame size
Answer: AD
NEW QUESTION 14
Refer to the Exhibit:
Refer to the exhibit. Which action do you take to ensure that the IP addresses in IP pool ext-mgmt are selected in a random order?
- A. Select the Default option in the Assignment Order property
- B. Delete all the IP pools except for IP pool ext-mgmt
- C. Add another block to IP pool ext-mgmt
- D. Select a pool size that is larger than 0
Answer: A
NEW QUESTION 15
Refer to the Exhibit:
You are integrating Cisco UCS Director with the ACI fabric. Where do you create the account type?
- A. Pods
- B. Managed Network Elements
- C. Multi-Domain Managers
- D. Bare Metal Agents
Answer: C
NEW QUESTION 16
Scenario
In this scenario, you will refer to screenshots about Cisco UCS B-Series servers and UCS Manager. Instructions
To access the multiple-choice questions, click on the numbered boxes on the left of the top panel. There are four multiple-choice questions with this task. Be sure to answer all four questions before selecting the Next button.


Refer to the screenshot in Exhibit 3. Which tab would you choose to determine that a user failed to login to Cisco IMC?
- A. Fault Summary
- B. System Event Log
- C. CIMC Log
- D. Logging Controls
Answer: C
Explanation: Reference:
http://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/gui/config/guide/1.5/b_Cisco_UCS_C-series_G
NEW QUESTION 17
Answer:
Explanation: 
NEW QUESTION 18
You need to implement a Cisco UCS system at a customer Site.
Which adapters and operating systems have preprovisioned adapter policies?
- A. Ethernet vNICs and Windows, OS X Serve
- B. and Oracle Solaris operating systems.
- C. Fibre Channel vNICs and Windows, FreeBSD, and Linux Operating systems.
- D. Ethernet vNICs and Windows, VMware, and Linux operating systems.
- E. Fibre Channel vNICs and Windows, Oracle Solaris, and Linux operating systems.
Answer: D
Explanation: Reference:
http://www.educationalcentre.co.uk/deploy-a-cisco-ucs-system-part-2-from-scratch-for-vmware-esxi/
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configu
NEW QUESTION 19
Which backup option must be used for a system restore?
- A. full state
- B. all configuration
- C. system configuration
- D. logical configuration
- E. incremental
Answer: A
NEW QUESTION 20
Which description of an import operation in Cisco UCS Manager is true?
- A. You can perform an import while the system is up and running.
- B. You can import only a configuration file that was exported from the same Cisco UCS Manager.
- C. You can import a configuration from a higher release to a lower release.
- D. You can schedule an import operation.
Answer: A
Explanation: You can perform an import while the system is up and running.
You can import any configuration file that was exported from Cisco UCS Manager. The file does not need to have been exported from the same Cisco UCS Manager. You cannot schedule an import operation.
Reference: https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/
UCSM_GUI_Configuration_Guide_141_chapter43.html#task_B89DEDCFCDE54E9C81E67C53FAC4DEC6 https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/AdminManagem b_Cisco_UCS_Admin_Mgmt_Guide_3_1_chapter_01001.pdf
You cannot import configuration from a higher release to a lower release.
Recommend!! Get the Full 300-175 dumps in VCE and PDF From Surepassexam, Welcome to Download: https://www.surepassexam.com/300-175-exam-dumps.html (New 349 Q&As Version)